Skip to main content

Kollmorgen Support Network

S700

This servo amplifier is comprised of a one- or three-phase power supply and a high-performance control unit housed in a single enclosure. This servo amplifier is available in 110VAC-480VAC models.

S701/S724 Part SchemeOpen the PDF
S748/S772 Part SchemeOpen the PDF
Online Help for S300/S700 (including ASCII Reference)Open the Help

See S300 & S700 Errors and Warnings for a comprehensive list of faults.

Hardware Expansions

Interfaces

Digital / Analog I/OsPosition Output (encoder emulation)Software InterfacesMultiFieldbusMultiFeedback
  • 2 programmable analog inputs
  • 4 programmable digital inputs
  • 2 programmable digital inputs/outputs (direction selectable)
  • 14 digital inputs and 8 outputs with expansion card I/O-14/08
  • 2 analog outputs with expansion card PosI/O- Monitor

S700 Hardware Revision Number

Following are tables for the required firmware versions for S700 drives based on their Hardware Revision.

S701y2...724y2 (STO Dual Channel)

Hardware RevisionFirmware VersionDateRemarksExport Classification
02.105.18 - 5.992010-02STO dual channel(S7xxy2), Memory card usable, certified safety, part number scheme changedAL-3A225
02.205.18_ND1 - 5.99_ND12014-12Dual use, new data structureAL-3A225
02.205.18_ND0 - 5.99_ND02014-12Non Dual use, new data structure-
02.30>=6.00_ND1*2017-04Dual use, single-cable motor connection possible, memory increasedAL-3A225
02.30>=6.00_ND0*2017-04Non Dual use, single-cable motor connection possible, memory increased-
For Firmware downgrade < 5.45 please contact your service partner

* can be downgraded to 5.45 - 5.99

S748/772

Hardware RevisionFirmware VersionDateRemarksExport Classification
01.01>= 5.002009-07Starting versionAL-3A225
02.10>= 5.182011-09certified safety, part number scheme changedAL-3A225
02.205.18_ND1 - 5.99_ND12014-12Dual use, new data structureAL-3A225
02.205.18_ND0 - 5.99_ND02014-12Non Dual use, new data structure-
02.30>=6.00_ND1*2017-04Dual use, single-cable motor connection possible, memory increasedAL-3A225
02.30>=6.00_ND0*2017-04Non Dual use, single-cable motor connection possible, memory increased-
For Firmware downgrade < 5.45 please contact your service partner

S701y1...724y1 (STO single channel), old product

Hardware RevisionFirmware VersionDateRemarksExport Classification
00.202.212007-01Starting version (S7xxy1)AL-3A225
01.212.50 to 3.492007-07short housing, X5,X6,X7 changedAL-3A225
02.003.50 to 4.992008-04X0/X8 inverted, EtherCAT onboard, charging circuit(parallel connectivity), single channel STOAL-3A225
02.10 (frozen)5.15 (frozen)2010-12 (frozen)Single Channel STO (S7xxy1), frozenAL-3A225
Fehlermeldung F17 German
Fehlermeldung F16 German
Tippbetrieb German
Fehlermeldung F15 German
Fehlermeldung F14 German
Fehlermeldung F13 German
Fehlermeldung F12 German
Fehlermeldung F11 German
Fehlermeldung F10 German