See S300 & S700 Errors and Warnings for a comprehensive list of faults.

S300 Hardware Revision Number

Hardware Revision Firmware Version Date Remarks Export Classification
02.01 2.18 to 3.74 2006-04 Starting version AL-3A225
02.10 (03.01) 3.75 to 3.99 2010-05 AS->STO, new approval AL-3A225
04.00 5.18 - 5.99 2011-05 New CPU AL-3A225
04.10 5.18_ND1 - 5.99_ND1 2014-12 Dual use, new data structure AL-3A225
04.10 5.18_ND0 - 5.99_ND0 2014-12 Non Dual use, new data structure -
04.20 >=6.00_ND1* 2017-04 Dual use, single-cable motor Connection possible, memory increased AL-3A225
04.20 >=6.00_ND0* 2017-04 Non Dual Use, single-cable motor Connection possible, memory increased -
For Firmewaredowngrade < 5.45 please contact your service partner
 
Procedures For Uploading and Downloading Drive Parameters With The S300 Drive English
FAQ Seiten German
Will…
Wie hoch ist der max. Wert für den Motortemperatur- Widerstand (PTC)? German
Will…
Servoverstärker German
Prüfimpuls German
Servoantrieb German
Servomotoren German
Sensorlos German
Sicherheitskonzept S300 German
What is the message level for amplitude error (F04) with SinCos encoders?

The SinCos amplitude monitoring enables the F04 error with:

  • FW 070 : F04 at approx. 1900 U/min
  • >=FW 072 : F04 at approx. 4500 U/min (approx. 150Khz)

The monitoring can be switched over in both firmware versions with CPHASE 2.

No communication to the encoder 

Solution: connect the encoder, check the cable 

Wrong data in the encoder 

This error occurs with new encoders, that have never been initialized.

Solution: Initialize the data with the command HSAVE (terminal screen)

See pages Supervision of Sine Cosine EncodersSetup of an Endat or Hiperface or BISS encoder and LED Display

How can the direction for an analog set point be inverted without changing the wiring?

Select function 30 for a digital input:

INHCMD VSCALE –x
INLCMD VSCALE x

For more information refer to Motion direction - Parameters

Are there differences in the motor databases of S300/S700 and S400/S600?

Yes. In the S300/S700 motor database (MDB) there isn't a single dataset per power stage and feedback. The parameter values are calculated depending on the set FBTYPE out of the same rough data. Criteria for a valid motor for the power stage is now:

0.25 * DICONT <= MICONT <= 4 * DICONT. 

The motor databases for S400/S600 cannot be used with S300/S700.

Why does n32 flash in the display?

The firmware of the amplifier is a beta version (not released). Refer to page LED Display Codes.

What is the maximum number of motion tasks that S300 can handle?

200 Flash motion tasks that can be saved in the device permanently, (number 1 to 200). 100 RAM motion tasks starting at number 201.