Skip to main content

Kollmorgen Support Network

S300

This servo amplifier is comprised of a three-phase power supply and a high-performance control unit housed in a single enclosure. This single axis servo amplifier is available in 110VAC-480VAC, 1,5-10A models.

  • MultiFeedback, MultiFieldbus
  • EMC - Mains Filter and Brake Resistor internally
  • Safety Function STO, SIL2, PLd

See S300 & S700 Errors and Warnings for a comprehensive list of faults.

S300 Hardware Revision Number

Hardware Revision Firmware Version Date Remarks Export Classification
02.01 2.18 to 3.74 2006-04 Starting version AL-3A225
02.10 (03.01) 3.75 to 3.99 2010-05 AS->STO, new approval AL-3A225
04.00 5.18 - 5.99 2011-05 New CPU AL-3A225
04.10 5.18_ND1 - 5.99_ND1 2014-12 Dual use, new data structure AL-3A225
04.10 5.18_ND0 - 5.99_ND0 2014-12 Non Dual use, new data structure -
04.20 >=6.00_ND1* 2017-04 Dual use, single-cable motor Connection possible, memory increased AL-3A225
04.20 >=6.00_ND0* 2017-04 Non Dual Use, single-cable motor Connection possible, memory increased -
For Firmewaredowngrade < 5.45 please contact your service partner
 
Mensagem de Erro F14 Portuguese, Brazil
Giuliano…
Mensagem de Erro F13 Portuguese, Brazil
Giuliano…
Mensagem de Erro F12 Portuguese, Brazil
Giuliano…
Mensagem de Erro F11 Portuguese, Brazil
Giuliano…
Mensagem de Erro F10 Portuguese, Brazil
Giuliano…
Mensagem de Erro F09 Portuguese, Brazil
Giuliano…
Mensagem de Erro F08 Portuguese, Brazil
Giuliano…
Mensagem de erro F07 Portuguese, Brazil
Giuliano…
Mensagem de Erro F06 Portuguese, Brazil
Giuliano…
How can I calculate the brake power?
How can I select a motion task with an analog input?
What does four quadrant operation mean?
What is the maximum value for motor temperature sensor (PTC)?

S300: 5.0 kOhm
S400: 2.0 kOhm
S600: 1.6 kOhm
S700: 5.0 kOhm

How can I start communication to the amplifier, if it doesn't boot correctly?

To start the amplifier in monitor mode, press both keys in the front panel simultaneously while when switching the drive on (24V on).

Why are large set point steps (e.g. 0 >> 7 V) with OPMODE = 5 not executed?

Input filter isn't set correctly. Increase filter time constant of the analog input.

What is the permitted length of the feedback cable?

Depends on the feedback type. See page MultiFeedback

What is the permitted length of the motor cable?
  • <10m: noise emission acc. to IEC 61800-3 category C2
  • >10m: noise emission acc. to IEC 61800-3 category C3
  • >25m: with motor choke 3YL (see Accessories Manual)
  • max: 50m

See Instructions Manual for more information.

How can I reset the amplifier parameters to manufacturer default in the monitor mode?

Hyperterminal:

CLR
SRMON>
booting...
on user request starting SRMON 0.66
SR-Monitor. Danaher Motion
(SRMON Rev 0.66 Dec 14 10:53:51 2004)
FPGA Initialisation done
SRMON> clr
SRMON>