Skip to main content

Kollmorgen Support Network

S300

This servo amplifier is comprised of a three-phase power supply and a high-performance control unit housed in a single enclosure. This single axis servo amplifier is available in 110VAC-480VAC, 1,5-10A models.

  • MultiFeedback, MultiFieldbus
  • EMC - Mains Filter and Brake Resistor internally
  • Safety Function STO, SIL2, PLd

See S300 & S700 Errors and Warnings for a comprehensive list of faults.

S300 Hardware Revision Number

Hardware Revision Firmware Version Date Remarks Export Classification
02.01 2.18 to 3.74 2006-04 Starting version AL-3A225
02.10 (03.01) 3.75 to 3.99 2010-05 AS->STO, new approval AL-3A225
04.00 5.18 - 5.99 2011-05 New CPU AL-3A225
04.10 5.18_ND1 - 5.99_ND1 2014-12 Dual use, new data structure AL-3A225
04.10 5.18_ND0 - 5.99_ND0 2014-12 Non Dual use, new data structure -
04.20 >=6.00_ND1* 2017-04 Dual use, single-cable motor Connection possible, memory increased AL-3A225
04.20 >=6.00_ND0* 2017-04 Non Dual Use, single-cable motor Connection possible, memory increased -
For Firmewaredowngrade < 5.45 please contact your service partner
 
Mensagem de Erro F23 Portuguese, Brazil
Giuliano…
Mensagem de Erro F22 Portuguese, Brazil
Giuliano…
Mensagem de Erro F21 Portuguese, Brazil
Giuliano…
Mensagem de Erro F20 Portuguese, Brazil
Giuliano…
Mensagem de Erro F19 Portuguese, Brazil
Giuliano…
Mensagem de Erro F18 Portuguese, Brazil
Giuliano…
Mensagem de Erro F17 Portuguese, Brazil
Giuliano…
Mensagem de Erro F16 Portuguese, Brazil
Giuliano…
Mensagem de Erro F15 Portuguese, Brazil
Giuliano…
Which settings are required for operating an induction machine?
What does Hardware Revision mean on the nameplate of the servo amplifier?

The Hardware Revision defines the development status of the servo amplifier. The same number can be found on the cover page of the instructions manual. Refer to page Hardware Revision Number.

What do I have to consider when using a residual current protective device (RCD) in a servo system?
Is it possible to use motors with a feedback system without commutation information as a primary feedback.

Yes. A Wake & Shake function determines the absolute position of the permanent Magnets in relationship to the stator windings. See page Wake and Shake.

What do the parameters on screen page U/F control mean?

The parameters are used to setup an induction machine without feedback (sensorless).

See pages Sensorless Control for Induction Machines (S300, S700) and Operating Induction Machines (S300-S700).

Is it possible to suppress the motor cogging?

Yes, but with S300 and S700 only. See page Cogging Suppression

What does Gray Code mean?

See the page GrayCode

Is full output current possible with S300 in single phase operation?

See the page Single Phase Operation

Which motion task profiles are pre-defined?