KAS Stepper Control with AKT2G slicesAKT2G-SM-L50-000 and AKT2G-SM-L15-000 EtherCAT stepper drives allow you to control Stepper motors up to 5 Amp (6.5 with fan cartridge AKT2G-AC-FAN-001) with a PDMM or PCMM controller. | Joe Parks |
July 12, 2021 | English |
HMI Operating System VersionsThe HMI displays the Windows Embedded version in the lower-left corner of the screen at boot time. For reference, the AKI and AKI2G models are as follows: | ![]() |
July 7, 2021 | English |
KAS v3.06 is now available!!New Features Kollmorgen E-Bus Stepper Integration: AKT2G-SM-L50-000 - Stepper motor terminal with incremental encoder, 50 V DC, 5 A (Imax), 2 phases AKT2G-SM-L15-000 - Stepper motor terminal with incremental encoder, 24 V DC, | ![]() |
June 23, 2021 | English |
Letter of Volatility for AKD2G DrivesKollmorgen Corporation (“Kollmorgen”) declares that the AKD2G drives have memory devices as shown in the table below. The non-volatile memory that may contain user settings and data may be cleared as indicated. | ![]() |
June 17, 2021 | English |
S300 & S700 Errors and WarningsThis content is extracted from the DriveGUI documentation. | ![]() |
June 2, 2021 | English |
Configuration of PLC Siemens S7-1500 ProfiNetTM and Kollmorgen AKD®2G-SPPThis is a guide to configure the PROFINET IRT communication in between the CPU S7-15xxTx-PN and the AKD2G-SPP PROFINET. The result is to manage both axes by means of the Technology Objects that the PLC provides. The axes will be configured in Velocity Mode and the PLC will handle the position loop… | ![]() |
April 27, 2021 | English |
Speedtec Cable Notice (O-Ring)AKM motors that have Speedtec ready connectors when paired with a 2G cable, which have Speedtec connectors, must have the motor O-ring removed for the two to pair completely. The motor O-ring will cause interference with the Speedtec locking mechanism on the cable connector. Once the O-ring has | ![]() |
March 29, 2021 | English |
AKD2G Gantry Application SetupA gantry system consists of two motors sharing a load with minimal wasted energy used in opposing each other. This document is an attempt to help with setup and use of the Kollmorgen gantry control embedded in the AKD2G two-axis drive. For the scope of this document, I will refer to the two axes… | ![]() |
March 29, 2021 | English |
Value Line Cable Update NoticeKollmorgen is excited to announce our new Value Line cable offering! | ![]() |
March 29, 2021 | English |
Don't know if you need a servo or stepper?
Enabling New Surgical Possibilities with High-Torque, Low-Temperature and Compact-Size Motors
Read MoreEngineer the Exceptional