AKD-C/N Safety Characteristic Data
Structure
STO
ISO 13849-1
IEC 62061
PFH [1/h]
SFF [%]
TM (Years)
AKD-C + 1 x AKD-N
global
PL d, CAT 3
SIL 2
2.99E-08
97.08
20
AKD-C + 8 x AKD-N
global
PL d, CAT 3
SIL 2
3.07E-08
99.44
20…
inglês
S701-724 Safety Characteristic DataSTO, no safety card
Device S701-724
Operation mode
EN 13849-1
EN 62061
PFHD (1/h)
TM (Years)
STO1/2-Enable
single channel
PLd, Cat.3
SIL CL2
7.05E-08
20
STO1-Enable+STO2-Enable
dual channel
PLd, Cat.3
SIL…
inglês
AKM Certifications
Safety
CCC
CE
UL
UR
cUL
cUR
EAC
RoHS
REACH
AKM
n/a
EN
EN (US) / DE (US) / DE (EU)
E61960
E61960
certificate
EN
EN
EAC Notes:
Low voltage (TP TC 020/2011)
EMC (TP TC 004/2011)
inglês
S748-772 Safety Characteristic DataThis is valid for drives with HWR >= 02.10.
Device S748-772
Operation mode
EN 13849-1
EN 62061
PFHD (1/h)
TM (Years)
STO1/2-Enable
single channel
PLd, Cat.3
SIL CL2
7.05E-08
20
STO1-Enable+STO2-Enable
dual…
inglês
AKD-C/N Certifications
Safety
CCC
CE
UL
cUL
EAC
RoHS6
RoHS10
REACH
WEEE
AKD-C
STO SIL2/PLd (EN 13849)
Safety Characteristic Data
–
DE / EN
E217428
E217428
DE.A15.BЖ.01244
EN & DE
EN
EN
EN & DE…
inglês
Characteristic Data Safe Feedback
Device Safe Hiperface Encoder
EN 13849-1
EN 62061
PFHD (1/h)
TM (years)
MTTFD (years)
Safe HIPERFACE Encoder SKS36S/SKM36S
PLd, Kat.3
SIL CL2
1.3E-08
20
847
inglês
KAS HMI, obsoleteThis article provides information on obsolete KAS HMI panels.
inglês
AKD DC Bus LinkThe DC bus link, or connections, of the AKD drive can be used to connect the DC bus of one drive to the DC bus of another drive. The connection is done in parallel between two or more drives, with the maximum number of drives being limited by the total sum of the current ratings, as specifi
inglês
AKD Control Loop Update Rates
Digital current controller (670 ns)
Digital speed controller (62,5 µs)
Digital position controller (250 µs)