S748-772 Safety Characteristic DataThis is valid for drives with HWR >= 02.10.
Device S748-772
Operation mode
EN 13849-1
EN 62061
PFHD (1/h)
TM (Years)
STO1/2-Enable
single channel
PLd, Cat.3
SIL CL2
7.05E-08
20
STO1-Enable+STO2-Enable
dual…
Inglese
AKD DC Bus LinkThe DC bus link, or connections, of the AKD drive can be used to connect the DC bus of one drive to the DC bus of another drive. The connection is done in parallel between two or more drives, with the maximum number of drives being limited by the total sum of the current ratings, as specifi
Inglese
KAS HMI, obsoleteThis article provides information on obsolete KAS HMI panels.
Inglese
AKD Control Loop Update Rates
Digital current controller (670 ns)
Digital speed controller (62,5 µs)
Digital position controller (250 µs)
Inglese
AKD MODBUS.MSGLOG and MODBUS.MSGDUMPMODBUS.MSGLOG and MODBUS.MSGDUMP
When MODBUS.MSGLOG is set to 1 it enables the logging of the raw Modbus data received by the drive via the report given by MODBUS.MSGDUMP.