Error Message F26
Valid for S300, S400, S600, S700
| Display | Meaning | Possible cause | Measure S300/S700 | Measure S400/S600 |
|---|---|---|---|---|
| F26 | Limit Switch Homing Error
Hardware Limit Switch reached (defined by REFLS) |
Cable brake (limit switches) | Check cable | Check cable |
| Connected limit switches do not belong to the axis. | Check and correct limit switch to axis assignment. | Check and correct limit switch to axis assignment. | ||
| No limit switches connected. | Disable input functions (Screen page I/O digital) | Disable input functions (Screen page I/O digital ) | ||
| Limit switches inverted | Assign PSTOP and NSTOP correctly to the inputs (Screen page I/O digital) | Assign PSTOP and NSTOP correctly to the inputs (Screen page I/O digital) |