Error Message F17
Valid for S300, S400, S600, S700
| Display | Meaning | Possible cause | Measure S300/S700 | Measure S400/S600 |
|---|---|---|---|---|
| F17 | A/D converter error |
Strong electromagnetic interference |
Reduce (EMC) interference; check shielding and earthing. Mount devices which generate electrical fields further away from the amplifier. |
Reduce (EMC) interference; check shielding and earthing. Mount devices which generate electrical fields further away from the amplifier. |
|
Hardware faulty |
Return the servo amplifier to manufacturer for repair |
Return the servo amplifier to manufacturer for repair |