Error Message F01
Valid for S300, S400, S600, S700
| Display | Meaning | Possible causes | Measures S300/S700 | MeasuresS400/S600 |
|---|---|---|---|---|
| F01 | Heat sink temperature too high | Ambient temperature too high | Max. value adjusted by manufacturer to 80°C. Decrease ambient temperature. | Max. value adjusted by manufacturer to 80°C. Decrease ambient temperature. |
| Amplifier contaminated | Check / blow out ventilation slots. Use air filters. | Check / blow out ventilation slots. Use air filters. | ||
| Fan defective / non-contacted | Check the air flow / fan noise; if defective, send the amplifier to the manufacturer for repair. | Check the air flow / fan noise; if defective, send the amplifier to the manufacturer for repair. | ||
| Value MAXTEMPH too small | Range 20 .. 85°C, default 80°C, increase MAXTEMPH | Range 20 .. 85°C, default 80°C, increase MAXTEMPH | ||
| No air flow due to restricted installation | Conversion of the switchgear cabinet. Install an air-conditioning unit. | Conversion of the switchgear cabinet. Install an air-conditioning unit. | ||
| Hardware faulty | Return the servo amplifier to manufacturer for repair | Return the servo amplifier to manufacturer for repair |