DICONT Parameter (S300-S700)
| 18 Aug 2014
|
|
DICONT Parameter (S300-S700)
| ASCII - Command |
DICONT |
|
|
| Syntax Transmit |
DICONT |
|
|
| Syntax Receive |
DICONT <Data> |
|
Available in |
|
| Type |
Variable ro |
|
MMI |
Yes |
| ASCII Format |
Float |
|
CANBus Object Number |
3527 (hex) |
| DIM |
A |
|
PROFIBUS PNU |
1639 (dec) IND = 1 (dec) |
| Range |
1.5 .. 20.0 |
|
DPR |
39 (dec) |
| Default |
Hardware Defined |
|
|
| Opmode |
All |
|
Data Type Bus/DPR |
Integer32 |
| Drive State |
- |
|
Weighting |
1000 |
| Start Firmware |
1.0 |
|
|
| Configuration |
No |
|
Last Change of this Object |
1.0 |
| Function Group |
actual values |
|
EEPROM |
No |
| Short Description |
Drive continuous current |
Description
| The continuous current rating of the drive. DICONT is depending on VBUSBAL for drive 403, 406, 614 and 670. |