Sporadic Error Message F04 with Linear Measuring SystemsWith linear measuring systems sporadic errors F04, have been observed. A possible solution could be the use of a double shielded signal cable. Connect the inner shield one one end to the outer shield (wide area connection) and connect the outer shield on both ends to ground. İngilizce