MI2T Parameter (S300-S700)
| 18 Aug 2014
|
|
MI2T Parameter (S300-S700)
| ASCII - Command |
MI2T |
|
|
| Syntax Transmit |
MI2T |
|
|
| Syntax Receive |
MI2T <Data> |
|
Available in |
|
| Type |
Variable ro |
|
MMI |
No |
| ASCII Format |
Integer8 |
|
CANBus Object Number |
35A4 (hex) |
| DIM |
% |
|
PROFIBUS PNU |
1764 (dec) IND = 1 (dec) |
| Range |
0 ... 100 |
|
DPR |
164 (dec) |
| Default |
- |
|
|
| Opmode |
All |
|
Data Type Bus/DPR |
Integer8 |
| Drive State |
|
|
Weighting |
|
| Start Firmware |
1.0 |
|
|
| Configuration |
No |
|
Last Change of this Object |
1.0 |
| Function Group |
motor |
|
EEPROM |
No |
| Short Description |
Motor I2T load |
Description
| This variable returns the average current as a percentage of the continuous current (see MICONT). The average current is filtered with the time constant MTIME. |