Configuring the SC900 & SCE900 Servo Drives for AKM Motors
Configuring the SC900 & SCE900 Servo Drives for AKM Motors
1. Click On-Line Tuning.
2. Under motors, click "Other..." at the bottom of the pull-down menu.
3. Enter current in Peak value, not RMS.
4. Enter number of motor poles, not pole-pairs.
5. Click OK and save the configuration
6. Set Commoff = 240. This is set in the program after saving the configuration.