Skip to main content

Kollmorgen Support Network

What is the resolution of the current controller?

The incremental current actual value (iq, q component) of the current controller is triggered two times within 62,5µs and the values are added but the average is not determined. 

Units: ±3280 = ±DIPEAK in IncrAmpere?
DIPEAK = device peak current