What is the message level for amplitude error (F04) with SinCos encoders?
The SinCos amplitude monitoring enables the F04 error with:
- Level min/max (see page Supervision of Sine Cosine Encoders)
- no communication to the encoder
Solution: connect the encoder, check the cable
- Wrong data in the encoder
This error occurs with new encoders, that have never been initialized
Solution: Initialize the data with the command HSAVE (terminal screen)
- Linear measuring system is used
Feedback cable shielding
Solution: see Sporadic Error Message F04 with Linear Measuring Systems
See pages Supervision of Sine Cosine Encoders, Setup of an Endat or Hiperface or BISS encoder, and AKD LED Display or Servostar LED Display.