AKD and AKD2G Resolver Excitation Output Voltage Specification
The AKD (1G and 2G) and Max capability is 20 V0-p or 14 Vrms. This supports down to a Ktr of 0.25. Please be aware that the AKD (1G and 2G) expects the SIN and COS input signals to be around 3.5 Vrms at max.
You set the FB#.RESKTR (AKD2G) or FB1.RESKTR (AKD1G) parameter () to set the resolver excitation amplitude.
Open circuit excitation amplitude = (3.5 Vrms)/(RESKTR).
Also note that the maximum load current is 75 mArms.