Diagnostic buffer of module CPU 315-2 PN/DP Order No./ Description Component Version 6ES7 315-2EH14-0AB0 Hardware 3 - - - Firmware V 3.2.3 Boot Loader Firmware expansion A 32.9.9 Rack: 0 Slot: 2 Serial number: S C-B6TJ63372011 Event 1 of 10: Event ID 16# 4302 Mode transition from STARTUP to RUN Startup information: - Startup with modified system configuration - Difference between setpoint and actual configuration - Time for time stamp at the last backed up power on - Single processor operation Current/last startup type: - Warm restart triggered via MPI; last power on backed up Permissibility of certain startup types: - Manual warm restart permitted - Automatic warm restart permitted Last valid operation or setting of automatic startup type at power on: - Warm restart triggered via MPI; last power on backed up Previous operating mode: STARTUP (warm restart) Requested operating mode: RUN Incoming event 02:29:58.954 PM 03/26/2020 (Coding: 16# 4302 FF68 C700 0000 0B14 7714) Event 2 of 10: Event ID 16# 1381 Request for manual warm restart STOP due to: STOP caused by PG stop operation or by SFB 20 "STOP" Startup information: - Startup with modified system configuration - Difference between setpoint and actual configuration - Time for time stamp at the last backed up power on - Single processor operation Current/last startup type: - Warm restart triggered via MPI; last power on backed up Permissibility of certain startup types: - Manual warm restart permitted - Automatic warm restart permitted Last valid operation or setting of automatic startup type at power on: - Warm restart triggered via MPI; last power on backed up Requested OB: Startup OB (OB100) Priority class: 27 Incoming event 02:29:58.952 PM 03/26/2020 (Coding: 16# 1381 1B64 C772 4304 0B14 7714) Event 3 of 10: Event ID 16# 4301 Mode transition from STOP to STARTUP STOP due to: STOP caused by PG stop operation or by SFB 20 "STOP" Startup information: - Startup with modified system configuration - Difference between setpoint and actual configuration - Time for time stamp at the last backed up power on - Single processor operation Current/last startup type: - Warm restart triggered via MPI; last power on backed up Permissibility of certain startup types: - Manual warm restart permitted - Automatic warm restart permitted Last valid operation or setting of the automatic startup type at power on: - Warm restart triggered via MPI; last power on backed up Previous operating mode: STOP (internal) Requested operating mode: STARTUP (warm restart) Incoming event 02:29:58.862 PM 03/26/2020 (Coding: 16# 4301 FF46 C772 4304 0B14 7714) Event 4 of 10: Event ID 16# 4304 STOP caused by PG stop operation or by SFB 20 "STOP" Previous operating mode: RUN Requested operating mode: STOP (internal) Incoming event 02:29:46.738 PM 03/26/2020 (Coding: 16# 4304 FF84 0000 0000 0000 0000) Event 5 of 10: Event ID 16# 2942 I/O access error, reading P area, word access, Access address: 288 Requested OB: I/O access error OB (OB122) Priority class: 1 External error, Incoming event 02:29:42.171 PM 03/26/2020 (Coding: 16# 2942 017A 0020 0120 0000 0000) Event 6 of 10: Event ID 16# 2942 I/O access error, reading P area, word access, Access address: 288 Requested OB: I/O access error OB (OB122) Priority class: 1 External error, Incoming event 02:29:42.168 PM 03/26/2020 (Coding: 16# 2942 017A 0020 0120 0000 0000) Event 7 of 10: Event ID 16# 2942 I/O access error, reading P area, word access, Access address: 288 Requested OB: I/O access error OB (OB122) Priority class: 1 External error, Incoming event 02:29:42.165 PM 03/26/2020 (Coding: 16# 2942 017A 0020 0120 0000 0000) Event 8 of 10: Event ID 16# 2942 I/O access error, reading P area, word access, Access address: 288 Requested OB: I/O access error OB (OB122) Priority class: 1 External error, Incoming event 02:29:42.163 PM 03/26/2020 (Coding: 16# 2942 017A 0020 0120 0000 0000) Event 9 of 10: Event ID 16# 2942 I/O access error, reading P area, word access, Access address: 288 Requested OB: I/O access error OB (OB122) Priority class: 1 External error, Incoming event 02:29:42.160 PM 03/26/2020 (Coding: 16# 2942 017A 0020 0120 0000 0000) Event 10 of 10: Event ID 16# 2942 I/O access error, reading P area, word access, Access address: 288 Requested OB: I/O access error OB (OB122) Priority class: 1 External error, Incoming event 02:29:42.158 PM 03/26/2020 (Coding: 16# 2942 017A 0020 0120 0000 0000)