I am looking for a wiring diagram that would show how to connect 6 drives (AKD-P01207-NBEI-0000) to 1 External Regen Resistor (BAR-1500-33). Please include fusing detail.

Thanks,

 

Comments & Answers

jcoleman02 said ...

jcoleman02 |

The AKD Installation manual has a section called "DC Bus Link" with a diagram showing 3 drives sharing the DC bus and one of them with external regen.  Connecting 6 drive would use the same connections.  Just make sure the drive with external regen can handle the regen current for all of the drive regening at any given time.