Skip to main content

Kollmorgen Support Network

Using a Cartdrige DDR with 120 VAC | 26 Oct 2015 | |

Using a Cartdrige DDR with 120 VAC

The Cartridge DDR specifications only list 230 400 and 480 VAC options. A C041A should be able to run off 110 VAC, right? Is there a speed torque curve available for the voltage?

Comments & Answers

jcoleman02 said ...

jcoleman02 | Mon, 10/26/2015 - 16:27

You can run the DDR and Cartridge DDR motor on a drive connected to 110, 115, 120 VAC.  You will just get a lower maximum speed, about half of that with 230VAC.

About this Question

spencer hepworth
Taxonomy: