Skip to main content

Kollmorgen Support Network

Linear Motor Service mode >

Hi, we are trying to operate ironcore ICH22-100 motor with AKD-P 012 07 servo driver. In the service mode in workbench in velocity mode, we see the velocity feedback to be oscillating and have a lot of noise and spikes when motor is at constant…

Linear Motor Analog Control >

Hi, Thank you to jcoleman02 for his support on my previous post. We have tried contacting the customer support a lot of times but to no avail :( I wanted to ask about encoder resolution. Since we are using a quadrature incremental encoder for…

Linear Motor Analog Control >

Hello everyone,  Thank you to Michael_Brown455 and jcoleman02 to reply to my previous posts. We were having issues with using the AKD driver with ICH Linear motor and as soon as we operated in Analog mode in the velocity loop, we started having…

Linear Motor Analog Control >

Hi everyone, We are using ironcore Linear Motor ICH22-100 for our operation. The motor is working fine in service mode (actually we do not know that how good it is working if we give it complex motions, but it is working smoothly for jog and…

Linear Motor Analog Control >

Hi everyone, We are using ironcore Linear Motor ICH22-100 for our operation. The motor is working fine in service mode (actually we do not know that how good it is working if we give it complex motions, but it is working smoothly for jog and…

ICH linear motor and maximum bus voltage >

Please, could you tell me if a ICH11-100-A5 linear motor could accept a DC vus voltage of 560 Vdc ? Thanks for your answer. Best regards.