Hi.

I have a question about option of the S200 Drive.

The option was 0x00000001, but we found that Option of the latest S/N(18H~) was 0x00000000.

Because of that, when replacing drives, Asynq occurs.

Please check on this problem.

Thank you.

Attachment 
0 Comments

1 Answer

0 votes
+ vote
Vote up!

Hello Ryu,

We have found a problem during production. It has since been fixed. All SynqNet S200 drives' product need to be Option 1. To change this option number, you can run the following command through the C:\Program Files (x86)\MEI\MDK\MEI_MDK_DIR\Win32:

 sqnodeeeprom productOption 1