Back to top

How to reset AKD Fault using Modbus TCP?

0 votes
+ vote
Vote up!
How to reset AKD Fault using Modbus TCP?
0 Comments

1 Answer

0 votes
+ vote
Vote up!

The drive command to reset a fault with the AKD is DRV.CLRFAULTS Modbus register 224. The command is executed in the drive if a value unequal zero is written to this register via Modbus. e.g. 1

http://curvegen.kollmorgen.com/webhelp/workbench/German/#CommandParamRefGuide/DRV/DRV.CLRFAULTS.htm?Highlight=drv.clear

For all the Modbus related article and examples there has been formed a landing page:

https://www.kollmorgen.com/en-us/developer-network/akd-modbus-tcp-landing-page/

This includes a lot of different examples and how to.

0 Comments