Back to top
Title Language File Type: Size Release Date
zip Firmware S700 (v6.08_ND0)
Firmware for S700 drives
Release: 6.08_ND0
English zip 2.02 MB 2/24/20
zip Firmware S700 (v6.07_ND0)
For drives with increased Memory size only, from Hardware Revision 2.30. Do not load to former drive versions. EN: Release of FW 6.07 for S700 (HW 2.3, 1 STO and 2 STO, all high-current). This firmware replaces the previous standard version 6.01. Changes in this version: Motor Support - support for motors with MPOLES>= 172 (this MPOLES setting was not possible because of MSPEED/SLJSWITCH deadlock). - Function for motor inductivity measurement (CALCML) - CALCHALL function implemented (testing of hall/motor assignment). - Support for motor data base 1.46 (AKM2G) Feedback support - VCOMM limit value extended to 25000 RPM - ramp function (ACCR) for analog position command (ANCNFG=8) - HDSL: Software reset for F04 implemented Fieldbus - PLL command can be accessed via Object Number 1057 - PROFIBUS: CONTINUE problem fixed (no automatically start of motion task after HALT OFF fixed) - Support for BISS-C multiturn implemented. BISSREVOL defines number of multiturn bits. - Pllhub is used not only for EtherCat but also for CAN and Aquarius - (only Synqnet,Sercos and Sigmatek are using constant value 2 instead of PLLHUB) - EtherCat: EIOBUF command for EtherCat mapping values implemented. DRIVE Bit 0x2000 reports support for CALCML and EIOBUF for the DriveGUI. Safety - SFD3 problem at switch on with DIR=20 and Safety card (error F31o19i02) fixed.
Release: 6.07_ND0
English zip 1.98 MB 3/26/19
zip Firmware S700 (v6.01_ND0)
SFD3 and HDSL suport. For drives with increased Memory size only, from Hardware Revision 2.30. Do not load to former drive versions. EN: Release of FW 6.01 for S700 (HW 2.3, 1 STO and 2 STO, all high-current). This firmware replaces the previous standard version 6.00. Elimination of problems with SFD3 communication. DE: Freigabe der FW 6.01 für S700 (HW 2.3, 1 STO und 2 STO, alle Stromstarken). Diese Firmware ersetzt die bisherige Standard-Version 6.00. Beseitigung der Probleme mit der SFD3-Kommunikation.
Release: 6.01_ND0
English zip 2.09 MB 11/11/17
zip Firmware S700 (v6.00_ND0)
SFD3 and HDSL suport. For drives with increased Memory size only, from Hardware Revision 2.30. Do not load to former drive versions.
Release: 6.00_ND0
English zip 2.08 MB 3/1/17
zip Firmware S700 (v5.87_ND0)
Firmware for S700 drives. Decimal places for ENCLINES and ENCIN implemented, Possibility for SSI reading via Macro program, SSIMASK implemented, Number of scope channels extended from 4 to 10.
Release: 5.87_ND0
English zip 1.37 MB 10/1/15
zip Firmware S700 (v3.89_ND0)
Firmware for S700 drives.
Release: 3.89
English zip 1.42 MB 1/1/10