Back to top

Error Message F17

Valid for S300, S400, S600, S700

Display Meaning Possible cause Measure S300/S700 Measure S400/S600
F17  A/D converter error

Strong electromagnetic interference 

Reduce (EMC) interference; check shielding and earthing. Mount devices which generate electrical fields further away from the amplifier. 

Reduce (EMC) interference; check shielding and earthing. Mount devices which generate electrical fields further away from the amplifier. 

Hardware faulty 

Return the servo amplifier to manufacturer for repair 

Return the servo amplifier to manufacturer for repair